Design · Concrete

Secant modulus of elasticity of concrete Ecm

  • Type: Property
  • Version 1
  • reviewed on 11/12/2026

Secant modulus of elasticity of concrete to EN 1992-1-1 Table 3.1: Ecm = 22 · (fcm / 10)⁰.3.

Ecm=22⋅(fcm10 MPa)0.3 GPa\displaystyle E_{cm} = 22 \cdot \left(\frac{f_{cm}}{10\text{ MPa}}\right)^{0.3}\text{ GPa}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

fcm

Formula and quantities

SymbolNameUnitNote
fcm\displaystyle f_{cm}Mean compressive strength of concrete (f_ck + 8 MPa)N/m²
Ecm\displaystyle E_{cm}Secant modulus of elasticity of concreteN/m²Result

Worked example

fcm\displaystyle f_{cm} = 38,000,000 N/m²

Ecm\displaystyle E_{cm} = 32,836,600,000 N/m² · Source: EN 1992-1-1:2004 Table 3.1

Scope and standard

Normal weight concrete to EN 1992-1-1.

Standard
EN 1992-1-1:2004, clause Table 3.1
Result
Ecm\displaystyle E_{cm} in GPa

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Ecm\displaystyle E_{cm} = 32,836,600,000 N/m²= (22 [GPa]) · (((38,000,000 N/m²) / 1 [MPa]) / 10)⁰.3

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Concrete.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.