Design · Concrete

Corbel primary tie design tensile force Ftd

  • Type: Action effect
  • Version 1
  • reviewed on 11/12/2026

Design tensile force in the primary tie of a reinforced concrete corbel to EN 1992-1-1 Annex J Eq. (J.2).

Ftd=FEd⋅cot⁡θ+HEd\displaystyle F_{td} = F_{\mathrm{Ed}} \cdot \cot\theta + H_{\mathrm{Ed}}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

Ftd

Formula and quantities

SymbolNameUnitNote
FEd\displaystyle F_{\mathrm{Ed}}Vertical design load applied to the corbelkN
cot⁡θ\displaystyle \cot\thetaCotangent of the angle theta of the compressive strut (cot(theta) = (a_c + 0.2*a_1) / z_0)1
HEd\displaystyle H_{\mathrm{Ed}}Horizontal design force acting on the corbel (H_Ed >= 0.2 * F_Ed)kN
Ftd\displaystyle F_{td}Design tensile force in primary tiekNResult

Worked example

FEd\displaystyle F_{\mathrm{Ed}} = 300 kN · cot⁡θ\displaystyle \cot\theta = 0.85 1 · HEd\displaystyle H_{\mathrm{Ed}} = 60 kN

Ftd\displaystyle F_{td} = 315 kN · Source: EN 1992-1-1:2004 Eq. (J.2)

Scope and standard

Short cantilevers and corbels to EN 1992-1-1 Annex J.

Standard
EN 1992-1-1:2004, clause J.3, Eq. (J.2)
Result
Ftd\displaystyle F_{td} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Ftd\displaystyle F_{td} = 315 kN= (300 kN) · (0.85 1) + (60 kN)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Concrete.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.