Design · Concrete

Longitudinal shear stress in flange vEd

  • Type: Action effect
  • Version 1
  • reviewed on 11/12/2026

Longitudinal shear stress at the junction between flange and web of a flanged beam to EN 1992-1-1 Eq. (6.20).

vEd=ΔFdhf⋅Δx\displaystyle v_{\mathrm{Ed}} = \frac{\Delta F_{\mathrm{d}}}{h_{f} \cdot \Delta x}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

hfvEdΔFd

Formula and quantities

SymbolNameUnitNote
ΔFd\displaystyle \Delta F_{\mathrm{d}}Change in normal force in outstand flange over section lengthkN
hf\displaystyle h_{f}Flange thickness at junction with webm
Δx\displaystyle \Delta xLength under consideration along the beam axism
vEd\displaystyle v_{\mathrm{Ed}}Longitudinal shear stress in flangeN/m²Result

Worked example

ΔFd\displaystyle \Delta F_{\mathrm{d}} = 120 kN · hf\displaystyle h_{f} = 0.15 m · Δx\displaystyle \Delta x = 0.8 m

vEd\displaystyle v_{\mathrm{Ed}} = 1,000,000 N/m² · Source: EN 1992-1-1:2004 Eq. (6.20)

Scope and standard

Flanges of reinforced concrete T-beams and box girders to EN 1992-1-1.

Standard
EN 1992-1-1:2004, clause 6.2.4 (3), Eq. (6.20)
Result
vEd\displaystyle v_{\mathrm{Ed}} in MPa

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
vEd\displaystyle v_{\mathrm{Ed}} = 1,000,000 N/m²= (120 kN) / ((0.15 m) · (0.8 m))

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Concrete.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.