Design · Concrete

Span-to-depth steel stress modification factor F3

  • Type: Coefficient
  • Version 1
  • reviewed on 11/12/2026

Modification factor for steel serviceability stress in allowable span-to-depth ratio to EN 1992-1-1 Clause 7.4.2 (2): F3 = 310 / σs.

F3=310 MPaσs\displaystyle F_{3} = \frac{310\text{ MPa}}{\sigma_{s}}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

σs

Formula and quantities

SymbolNameUnitNote
σs\displaystyle \sigma_{s}Tensile stress in steel reinforcement under quasi-permanent loadN/m²
F3\displaystyle F_{3}Steel stress modification factor1Result

Worked example

σs\displaystyle \sigma_{s} = 250,000,000 N/m²

F3\displaystyle F_{3} = 1.24 1 · Source: EN 1992-1-1:2004 clause 7.4.2 (2)

Scope and standard

Reinforced concrete beams and slabs to EN 1992-1-1.

Standard
EN 1992-1-1:2004, clause 7.4.2 (2)
Result
F3\displaystyle F_{3} in 1

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
F3\displaystyle F_{3} = 1.24 1= (310 [MPa]) / (250,000,000 N/m²)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Concrete.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.