Design · Concrete

Strength reduction factor nu1 for cracked concrete struts

  • Type: Coefficient
  • Version 1
  • reviewed on 11/9/2026

Strength reduction factor for concrete cracked in shear according to EN 1992-1-1: ν1 = 0.6 · (1 - fck / (250 MPa)).

ν1=0.6⋅(1−fck250)\displaystyle \nu_{1} = 0.6 \cdot \left(1 - \frac{f_{ck}}{250}\right)
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

fck

Formula and quantities

SymbolNameUnitNote
fck\displaystyle f_{ck}Characteristic compressive strengthN/mm²
ν1\displaystyle \nu_{1}Strut strength reduction factor–Result

Worked example

fck\displaystyle f_{ck} = 30 N/mm²

ν1\displaystyle \nu_{1} = 0.528 · Source: EN 1992-1-1:2004 Eq. (6.9)

Scope and standard

Reinforced concrete members designed using the variable strut inclination method (EN 1992-1-1, clause 6.2.3).

Standard
EN 1992-1-1:2004, clause 6.2.3 (3), Eq. (6.9)
Result
ν1\displaystyle \nu_{1} (dimensionless)

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
ν1\displaystyle \nu_{1} = 0.528= 0.6 · (1 - (30 N/mm²) / (250 [N/mm²]))

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Concrete.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.