Design · Concrete

Effective flange width of a symmetric T-beam

  • Type: Definition
  • Version 1
  • reviewed on 11/9/2026

Total effective flange width of a symmetric T-beam according to EN 1992-1-1: beff = bw + beff1 + beff2.

beff=bw+beff,1+beff,2\displaystyle b_{\mathrm{eff}} = b_{w} + b_{\mathrm{eff},1} + b_{\mathrm{eff},2}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

beff

Formula and quantities

SymbolNameUnitNote
bw\displaystyle b_{w}Web widthm
beff,1\displaystyle b_{\mathrm{eff},1}Effective flange outstand width on side 1m
beff,2\displaystyle b_{\mathrm{eff},2}Effective flange outstand width on side 2m
beff\displaystyle b_{\mathrm{eff}}Total effective flange widthmResult

Worked example

bw\displaystyle b_{w} = 0.3 m · beff,1\displaystyle b_{\mathrm{eff},1} = 0.6 m · beff,2\displaystyle b_{\mathrm{eff},2} = 0.6 m

beff\displaystyle b_{\mathrm{eff}} = 1.5 m · Source: EN 1992-1-1:2004 Eq. (5.7)

Scope and standard

T-beams and hollow core slabs under bending according to EN 1992-1-1, clause 5.3.2.1.

Standard
EN 1992-1-1:2004, clause 5.3.2.1, Eq. (5.7)
Result
beff\displaystyle b_{\mathrm{eff}} in m

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
beff\displaystyle b_{\mathrm{eff}} = 1.5 m= (0.3 m) + (0.6 m) + (0.6 m)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Concrete.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.