Design · Concrete
Effective height factor lambda for compression zone
Factor lambda defining the effective depth of the rectangular compression zone when fck > 50 MPa: λ = 0.8 - (fck - 50 MPa) / (400 MPa).
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Characteristic compressive strength | N/mm² | ||
| Effective compression zone factor | – | Result |
Worked example
= 70 N/mm²
= 0.75 · Source: EN 1992-1-1:2004 Eq. (3.19)
Scope and standard
High-strength concrete with 50 MPa < f_ck <= 90 MPa (for f_ck <= 50 MPa, lambda = 0.8).
- Standard
- EN 1992-1-1:2004, clause 3.1.7 (3), Eq. (3.19)
- Result
- (dimensionless)
Reference to clause and equation, no standard text. The description is written in our own words.