Design · Concrete

Fire design bending resistance of RC beam (EN 1992-1-2)

  • Type: Resistance
  • Version 1
  • reviewed on 11/21/2026

Design bending moment resistance in fire for a singly reinforced concrete section according to EN 1992-1-2 Annex B.1 / Annex E: MRdfi = As · fsdfi · zfi.

MRd,fi=As⋅fsd,fi⋅zfi\displaystyle M_{\mathrm{Rd},fi} = A_{s} \cdot f_{sd,fi} \cdot z_{fi}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

zfiAsMRdfi

Formula and quantities

SymbolNameUnitNote
As\displaystyle A_{s}Cross-sectional area of tension reinforcementmm²
fsdfi\displaystyle f_{sdfi}Design yield strength of reinforcement at fire temperatureN/m²
zfi\displaystyle z_{fi}Internal lever arm in firemm
MRdfi\displaystyle M_{Rdfi}Design bending moment resistance in firekNmResult

Worked example

As\displaystyle A_{s} = 1,200 mm² · fsdfi\displaystyle f_{sdfi} = 390,000,000 N/m² · zfi\displaystyle z_{fi} = 450 mm

MRdfi\displaystyle M_{Rdfi} = 210.6 kNm

Standard and source

Result
MRdfi\displaystyle M_{Rdfi} in kNm

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
MRdfi\displaystyle M_{Rdfi} = 210.6 kNm= (1,200 mm²) · (390,000,000 N/m²) · (450 mm)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Concrete.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.