Design · Concrete
Fire design bending resistance of RC beam (EN 1992-1-2)
Design bending moment resistance in fire for a singly reinforced concrete section according to EN 1992-1-2 Annex B.1 / Annex E: MRdfi = As · fsdfi · zfi.
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Cross-sectional area of tension reinforcement | mm² | ||
| Design yield strength of reinforcement at fire temperature | N/m² | ||
| Internal lever arm in fire | mm | ||
| Design bending moment resistance in fire | kNm | Result |
Worked example
= 1,200 mm² · = 390,000,000 N/m² · = 450 mm
= 210.6 kNm
Standard and source
- Standard
- EN 1992-1-2:2004
- Result
- in kNm
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
- Explain the formulastep by step
- Calculate for my memberwith Mia in CALC
- Compare with RFEM/RSTAB resultshand calculation versus model
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
The search starts in Design › Concrete.
Miaknows the formula catalog and asks for what is missing.