Design · Concrete

Time-dependent prestress loss (creep, shrinkage, relaxation) Δσ,p,c+s+r (EN 1992-1-1)

  • Type: Property
  • Version 1
  • reviewed on 11/25/2026

Combined time-dependent prestress stress loss due to concrete creep, shrinkage, and tendon relaxation according to EN 1992-1-1 Clause 5.10.6(2) Eq. (5.46): Δσp,c+s+r = (epscs · Ep + 0.8 · Δσpr + (Ep / Ecm) · φ · σc,QP) / (1 + (Ep / Ecm) · (Ap / Ac) · (1 + (Ac / Ic) · zcp²) · (1 + 0.8 · φ)).

Δσp,c+s+r=εcs⋅Ep+0.8⋅Δσpr+EpEcm⋅ϕ⋅σc,QP1+EpEcm⋅ApAc⋅(1+AcIc⋅zcp2)⋅(1+0.8⋅ϕ)\displaystyle \Delta\sigma_{p,c+s+r} = \frac{\varepsilon_{cs} \cdot E_{p} + 0.8 \cdot \Delta\sigma_{pr} + \frac{E_{p}}{E_{cm}} \cdot \phi \cdot \sigma_{\mathrm{c},QP}}{1 + \frac{E_{p}}{E_{cm}} \cdot \frac{A_{p}}{A_{\mathrm{c}}} \cdot \left(1 + \frac{A_{\mathrm{c}}}{I_{\mathrm{c}}} \cdot z_{cp}^2\right) \cdot (1 + 0.8 \cdot \phi)}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

zcpΔσp,c+s+rApEp

Formula and quantities

SymbolNameUnitNote
epscs\displaystyle eps_{cs}Estimated drying and autogenous shrinkage strain (positive)1
Ep\displaystyle E_{p}Modulus of elasticity of prestressing steelN/m²
Δσpr\displaystyle \Delta\sigma_{pr}Prestress stress loss due to tendon relaxationN/m²
Ecm\displaystyle E_{cm}Secant modulus of elasticity of concreteN/m²
ϕ\displaystyle \phiConcrete creep coefficient1
σc,QP\displaystyle \sigma_{\mathrm{c},QP}Concrete stress adjacent to tendons under quasi-permanent loadsN/m²
Ap\displaystyle A_{p}Cross-sectional area of prestressing tendonmm²
Ac\displaystyle A_{\mathrm{c}}Cross-sectional area of concrete sectionmm²
Ic\displaystyle I_{\mathrm{c}}Second moment of area of concrete sectionmm⁴
zcp\displaystyle z_{cp}Distance between centroid of concrete section and tendonsmm
Δσp,c+s+r\displaystyle \Delta\sigma_{p,c+s+r}Time-dependent prestress stress lossN/m²Result

Worked example

epscs\displaystyle eps_{cs} = 0.0003 · Ep\displaystyle E_{p} = 195,000,000,000 N/m² · Δσpr\displaystyle \Delta\sigma_{pr} = 40,000,000 N/m² · Ecm\displaystyle E_{cm} = 35,000,000,000 N/m² · ϕ\displaystyle \phi = 2 · σc,QP\displaystyle \sigma_{\mathrm{c},QP} = 8,000,000 N/m² · Ap\displaystyle A_{p} = 1,500 mm² · Ac\displaystyle A_{\mathrm{c}} = 300,000 mm² · Ic\displaystyle I_{\mathrm{c}} = 22,500,000,000 mm⁴ · zcp\displaystyle z_{cp} = 350 mm

Δσp,c+s+r\displaystyle \Delta\sigma_{p,c+s+r} = 150,868,000 N/m²

Standard and source

Result
Δσp,c+s+r\displaystyle \Delta\sigma_{p,c+s+r} in MPa

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Δσp,c+s+r\displaystyle \Delta\sigma_{p,c+s+r} = 150,868,000 N/m²= ((0.0003 1) · (195,000,000,000 N/m²) + 0.8 · (40,000,000 N/m²) + ((195,000,000,000 N/m²) / (35,000,000,000 N/m²)) · (2 1) · (8,000,000 N/m²)) / (1 + ((195,000,000,000 N/m²) / (35,000,000,000 N/m²)) · ((1,500 mm²) / (300,000 mm²)) · (1 + ((300,000 mm²) / (22,500,000,000 mm⁴)) · (350 mm)²) · (1 + 0.8 · (2 1)))

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Concrete.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.