Design · Concrete
Upper characteristic prestressing force Pk,sup (EN 1992-1-1)
Upper characteristic value of the prestressing force for serviceability and fatigue verifications according to EN 1992-1-1 Clause 5.10.9(1): Pk,sup = rsup · Pmt.
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Upper prestress scatter factor (typically 1.10) | 1 | ||
| Mean long-term prestressing force | kN | ||
| Upper characteristic prestressing force | kN | Result |
Worked example
= 1.1 · = 2,000 kN
= 2,200 kN
Standard and source
- Standard
- EN 1992-1-1:2004
- Result
- in kN
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
- Explain the formulastep by step
- Calculate for my dimensionsenter values, check the result
- Compare with a catalog sectionformula value and table value
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
The search starts in Design › Concrete.
Miaknows the formula catalog and asks for what is missing.