Design · Concrete

Upper characteristic prestressing force Pk,sup (EN 1992-1-1)

  • Type: Property
  • Version 1
  • reviewed on 11/25/2026

Upper characteristic value of the prestressing force for serviceability and fatigue verifications according to EN 1992-1-1 Clause 5.10.9(1): Pk,sup = rsup · Pmt.

Pk,sup=rsup⋅Pmt\displaystyle P_{k,sup} = r_{sup} \cdot P_{mt}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

PksupPmtrsup

Formula and quantities

SymbolNameUnitNote
rsup\displaystyle r_{sup}Upper prestress scatter factor (typically 1.10)1
Pmt\displaystyle P_{mt}Mean long-term prestressing forcekN
Pk,sup\displaystyle P_{k,sup}Upper characteristic prestressing forcekNResult

Worked example

rsup\displaystyle r_{sup} = 1.1 · Pmt\displaystyle P_{mt} = 2,000 kN

Pk,sup\displaystyle P_{k,sup} = 2,200 kN

Standard and source

Result
Pk,sup\displaystyle P_{k,sup} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Pk,sup\displaystyle P_{k,sup} = 2,200 kN= (1.1 1) · (2,000 kN)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Concrete.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.