Concrete design compressive strength in fire fcd,fi (EN 1992-1-2)
Design compressive strength of concrete at elevated temperature according to EN 1992-1-2 Clause 2.3 Eq. (2.2): fcdfi = (kc · fck) / γMfi.
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Temperature reduction factor for concrete compressive strength | 1 | ||
| Characteristic compressive cylinder strength of concrete | N/m² | ||
| Partial factor for concrete in fire (typically 1.0) | 1 | ||
| Design compressive strength of concrete in fire | N/m² | Result |
Worked example
= 0.6 1 · = 30,000,000 N/m² · = 1 1
= 18,000,000 N/m²
Standard and source
- Standard
- EN 1992-1-2:2004
- Result
- in MPa
Reference to clause and equation, no standard text. The description is written in our own words.