Actions and loads · Snow loads

Drift snow load at roof projection

  • Type: Definition
  • Version 1

Local snow load caused by drift accumulation at roof steps or projections.

s=μ2⋅sk\displaystyle s = \mu_{2} \cdot s_{k}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

ssk

Formula and quantities

SymbolNameUnitNote
μ2\displaystyle \mu_{2}Drift shape coefficient–
sk\displaystyle s_{k}Characteristic ground snow loadkN/m²
s\displaystyle sDrift snow loadkN/m²Result

Worked example

μ2\displaystyle \mu_{2} = 2 · sk\displaystyle s_{k} = 1.2 kN/m²

s\displaystyle s = 2.4 kN/m² · Source: hand calculation

Scope and standard

Eurocode 1 (EN 1991-1-3:2003) Section 5.3.6.

Result
s\displaystyle s in kN/m²

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
s\displaystyle s = 2.4 kN/m²= 2 · (1.2 kN/m²)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Actions and loads › Snow loads.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.