Actions and loads · Snow loads

Flat roof snow load pf (ASCE 7)

  • Type: Action
  • Version 1
  • reviewed on 11/15/2026

Flat roof snow load pf according to ASCE/SEI 7-22 Section 7.3 Eq. 7.3-1: pf = 0.7 · Ce · Ct · Is · pg.

pf=0.7⋅Ce⋅Ct⋅Is⋅pg\displaystyle p_{f} = 0.7 \cdot C_{e} \cdot C_{t} \cdot I_{s} \cdot p_{g}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

pfpg

Formula and quantities

SymbolNameUnitNote
Ce\displaystyle C_{e}Exposure factor1
Ct\displaystyle C_{t}Thermal factor1
Is\displaystyle I_{s}Importance factor for snow1
pg\displaystyle p_{g}Ground snow loadN/m²
pf\displaystyle p_{f}Flat roof snow loadN/m²Result

Worked example

Ce\displaystyle C_{e} = 1 1 · Ct\displaystyle C_{t} = 1 1 · Is\displaystyle I_{s} = 1 1 · pg\displaystyle p_{g} = 1,500 N/m²

pf\displaystyle p_{f} = 1,050 N/m²

Standard and source

Standard
ASCE 7-22
Result
pf\displaystyle p_{f} in kPa

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
pf\displaystyle p_{f} = 1,050 N/m²= 0.7 · (1 1) · (1 1) · (1 1) · (1,500 N/m²)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Actions and loads › Snow loads.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.