Structural analysis · Dynamics
Critical viscous damping coefficient
Critical damping coefficient separating oscillatory from aperiodic motion: ccr = 2 · √(k · m).
- General formula, independent of standards
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Spring stiffness | kN/m | > 0 | |
| Oscillating mass | kg | > 0 | |
| Critical damping coefficient | N·s/m | Result |
Worked example
= 100 kN/m · = 1,000 kg
= 20,000 N·s/m · Source: hand calculation
Scope and standard
Viscously damped single-degree-of-freedom oscillator.
- Result
- in N*s/m
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
- Explain the formulastep by step
- Calculate for my dimensionsenter values, check the result
- Compare with a catalog sectionformula value and table value
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
The search starts in Structural analysis › Dynamics.
Miaknows the formula catalog and asks for what is missing.