Structural analysis · Dynamics

Viscous damping ratio

  • Type: Property
  • Version 1
  • reviewed on 11/13/2026

Dimensionless viscous damping ratio relative to critical damping: ξ = c / (2 · √(k · m)).

ξ=c2k⋅m\displaystyle \xi = \frac{c}{2\sqrt{k \cdot m}}
  • General formula, independent of standards
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

mkcξ

Formula and quantities

SymbolNameUnitNote
c\displaystyle cViscous damping coefficientN·s/mc\displaystyle c ≥ 0
k\displaystyle kSpring stiffnesskN/mk\displaystyle k > 0
m\displaystyle mOscillating masskgm\displaystyle m > 0
ξ\displaystyle ξDamping ratio–Result

Worked example

c\displaystyle c = 1,000 N·s/m · k\displaystyle k = 100 kN/m · m\displaystyle m = 1,000 kg

ξ\displaystyle ξ = 0.05 · Source: hand calculation

Scope and standard

Viscously damped single-degree-of-freedom oscillator.

Result
ξ\displaystyle ξ (dimensionless)

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
ξ\displaystyle ξ = 0.05= (1,000 N·s/m) / (2 · sqrt((100 kN/m) · (1,000 kg)))