Structural analysis · Dynamics

Dynamic amplification factor for harmonic excitation

  • Type: Coefficient
  • Version 1
  • reviewed on 11/13/2026

Ratio of dynamic steady-state amplitude to static displacement under harmonic force: D = 1 / √((1 - r²)² + (2 · ξ · r)²).

D=1(1−r2)2+(2ξr)2\displaystyle D = \frac{1}{\sqrt{(1 - r^2)^2 + (2\xi r)^2}}
  • General formula, independent of standards
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

ξDr

Formula and quantities

SymbolNameUnitNote
r\displaystyle rFrequency ratio omega / omega_n–r\displaystyle r ≥ 0
ξ\displaystyle ξViscous damping ratio–ξ\displaystyle ξ ≥ 0
D\displaystyle DDynamic amplification factor–Result

Valid if(1−r2)2+(2⋅ξ⋅r)2>0\displaystyle (1 - r ^ 2) ^ 2 + (2 \cdot ξ \cdot r) ^ 2 > 0

Worked example

r\displaystyle r = 0.8 · ξ\displaystyle ξ = 0.05

D\displaystyle D = 2.71163 · Source: hand calculation

Scope and standard

Harmonic force excitation with frequency ratio r = omega / omega_n.

Result
D\displaystyle D (dimensionless)

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

D\displaystyle D = 2.71163= 1 / sqrt((1 - 0.8 ^ 2) ^ 2 + (2 · 0.05 · 0.8) ^ 2)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Structural analysis › Dynamics.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.