Geotechnics · Earth pressure
Maximum trapezoidal base contact pressure (EN 1997-1)
Maximum edge contact pressure under a strip foundation or retaining wall base with eccentricity e <= B / 6 (no uplift) according to EN 1997-1 Clause 6.5: σmax = (Vd / B) · (1 + (6 · e) / B).
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Design vertical load per unit wall length | kN/m | ||
| Foundation base width | m | ||
| Load eccentricity (e <= B/6) | m | ||
| Maximum edge contact pressure | N/m² | Result |
Worked example
= 240 kN/m · = 2.4 m · = 0.3 m
= 175,000 N/m²
Standard and source
- Standard
- EN 1997-1:2004
- Result
- in kPa
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
- Explain the formulastep by step
- Clarify values for my siteaccording to the national annex
- Calculate for my memberwith Mia in CALC
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
The search starts in Geotechnics › Earth pressure.
Miaknows the formula catalog and asks for what is missing.