Geotechnics · Bearing resistance

Sliding resistance verification ratio

  • Type: Verification
  • Version 1
  • reviewed on 11/12/2026

Verification of foundation against sliding failure: ηslide = Hd / Rhd <= 1.0.

ηslide=HdRh,d\displaystyle \eta_\mathrm{slide} = \frac{H_{\mathrm{d}}}{R_{h,\mathrm{d}}}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

HdRh,dηslide

Formula and quantities

SymbolNameUnitNote
Hd\displaystyle H_{\mathrm{d}}Design horizontal load on foundationkN
Rh,d\displaystyle R_{h,\mathrm{d}}Design sliding resistance of basekN
ηslide\displaystyle \eta_\mathrm{slide}Sliding verification ratio–Result

Worked example

Hd\displaystyle H_{\mathrm{d}} = 200 kN · Rh,d\displaystyle R_{h,\mathrm{d}} = 250 kN

ηslide\displaystyle \eta_\mathrm{slide} = 0.8 · Source: EN 1997-1:2004 clause 6.5.3

Scope and standard

Sliding limit state (GEO) for shallow foundations according to EN 1997-1 Clause 6.5.3.

Standard
EN 1997-1:2004, clause 6.5.3, Eq. (6.2)
Result
ηslide\displaystyle \eta_\mathrm{slide} (dimensionless)

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
ηslide\displaystyle \eta_\mathrm{slide} = 0.8= (200 kN) / (250 kN)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Geotechnics › Bearing resistance.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.