Effective thickness hw for deflection of a 2-ply laminated glass pane with shear transfer coefficient omega: hw = cbrt(h1³ + h2³ + 12 · ω · (h1 · h2 / (h1 + h2)) · hm²).

hw=cbrt(h13+h23+12⋅ω⋅(h1⋅h2/(h1+h2))⋅hm2)\displaystyle h_{w} = cbrt(h_{1}^3 + h_{2}^3 + 12 \cdot \omega \cdot (h_{1} \cdot h_{2} / (h_{1} + h_{2})) \cdot h_{m}^2)
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

hw

Formula and quantities

SymbolNameUnitNote
h1\displaystyle h_{1}Thickness of glass ply 1mm
h2\displaystyle h_{2}Thickness of glass ply 2mm
hm\displaystyle h_{m}Distance between ply mid-planesmm
ω\displaystyle \omegaInterlayer shear transfer coefficient (0 to 1)1
hw\displaystyle h_{w}Effective thickness for deflectionmmResult

Worked example

h1\displaystyle h_{1} = 10 mm · h2\displaystyle h_{2} = 10 mm · hm\displaystyle h_{m} = 11.52 mm · ω\displaystyle \omega = 0.25

hw\displaystyle h_{w} = 15.86 mm

Standard and source

Result
hw\displaystyle h_{w} in mm

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
hw\displaystyle h_{w} = 15.8616 mm= cbrt((10 mm)³ + (10 mm)³ + 12 · (0.25 1) · ((10 mm) · (10 mm) / ((10 mm) + (10 mm))) · (11.52 mm)²)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Glass.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.