Design · Glass

Glass load duration factor kmod (EN 16612)

  • Type: Property
  • Version 1
  • reviewed on 11/25/2026

Factor kmod for the duration of load acting on annealed glass according to EN 16612 Clause 8.1.3 Eq. (1): kmod = 0.663 · (tL / 1 s)^(-1/16).

kmod=0.663⋅tL(−1/16)\displaystyle k_{mod} = 0.663 \cdot t_{L}^(-1/16)
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

kmod

Formula and quantities

SymbolNameUnitNote
tL\displaystyle t_{L}Equivalent load durations
kmod\displaystyle k_{mod}Load duration modification factor1Result

Worked example

tL\displaystyle t_{L} = 5 s

kmod\displaystyle k_{mod} = 0.599553

Standard and source

Result
kmod\displaystyle k_{mod} in 1

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

kmod\displaystyle k_{mod} = 0.599553 1= 0.663 · ((5 s) / 1 [s])^(-1 / 16)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Glass.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.