Cross-sections · Open thin-walled sections

Flange outstand slenderness c/tf of an I-section

  • Type: Property
  • Version 1

Flange outstand width-to-thickness ratio for local buckling classification: c / tf = (b - tw) / (2 · tf).

ctf=b−tw2⋅tf\displaystyle \frac{c}{t_{f}} = \frac{b - t_{w}}{2 \cdot t_{f}}
  • General formula, independent of standards
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

yzbtftw

Formula and quantities

SymbolNameUnitNote
b\displaystyle bWidthmmb\displaystyle b > 0
tw\displaystyle t_{w}Web thicknessmmtw\displaystyle t_{w} > 0
tf\displaystyle t_{f}Flange thicknessmmtf\displaystyle t_{f} > 0
c/tf\displaystyle c/t_{f}Flange slenderness ratio–Result

Valid iftw<b\displaystyle t_{w} < b

Worked example

b\displaystyle b = 150 mm · tw\displaystyle t_{w} = 8 mm · tf\displaystyle t_{f} = 12 mm

c/tf\displaystyle c/t_{f} = 5.917 · Source: hand calculation: (150 - 8) / 24 = 5.9167

Scope and standard

I-section, EN 1993-1-1 Table 5.2.

Result
c/tf\displaystyle c/t_{f} (dimensionless)

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
c/tf\displaystyle c/t_{f} = 5.91667= ((150 mm) - (8 mm)) / (2 · (12 mm))

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Cross-sections › Open thin-walled sections.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.