Actions and loads · Combinations of actions

LRFD basic dead + live + roof live combination (ASCE 7)

  • Type: Action
  • Version 1
  • reviewed on 11/15/2026

Basic LRFD strength design load combination 2 according to ASCE/SEI 7-22 Section 2.3.1: U = 1.2 · D + 1.6 · L + 0.5 · Lr.

U=1.2⋅D+1.6⋅L+0.5⋅Lr\displaystyle U = 1.2 \cdot D + 1.6 \cdot L + 0.5 \cdot L_{r}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

DLLrU

Formula and quantities

SymbolNameUnitNote
D\displaystyle DDead load effectkN
L\displaystyle LLive load effectkN
Lr\displaystyle L_{r}Roof live load effectkN
U\displaystyle UFactored LRFD load effectkNResult

Worked example

D\displaystyle D = 100 kN · L\displaystyle L = 50 kN · Lr\displaystyle L_{r} = 20 kN

U\displaystyle U = 210 kN

Standard and source

Standard
ASCE 7-22
Result
U\displaystyle U in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
U\displaystyle U = 210 kN= 1.2 · (100 kN) + 1.6 · (50 kN) + 0.5 · (20 kN)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Actions and loads › Combinations of actions.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.