Design · Masonry

Design vertical load resistance of masonry wall per unit length

  • Type: Resistance
  • Version 1
  • reviewed on 11/13/2026

Design vertical resistance of an unreinforced masonry wall per unit length: NRd = Φ · t · fd.

NRd=Φ⋅t⋅fd\displaystyle N_{\mathrm{Rd}} = \Phi \cdot t \cdot f_{\mathrm{d}}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

NRdtfdΦ

Formula and quantities

SymbolNameUnitNote
Φ\displaystyle ΦCapacity reduction factor (min of Phi_i and Phi_m)–Φ\displaystyle Φ ≥ 0, ≤ 1
t\displaystyle tThickness of masonry wallmmt\displaystyle t > 0
fd\displaystyle f_{\mathrm{d}}Design compressive strength of masonryN/mm²fd\displaystyle f_{\mathrm{d}} > 0
NRd\displaystyle N_{\mathrm{Rd}}Design vertical resistance per unit lengthkN/mResult

Worked example

Φ\displaystyle Φ = 0.65 · t\displaystyle t = 240 mm · fd\displaystyle f_{\mathrm{d}} = 3 N/mm²

NRd\displaystyle N_{\mathrm{Rd}} = 468 kN/m · Source: hand calculation

Scope and standard

Unreinforced masonry walls under vertical loading according to EN 1996-1-1, clause 6.1.2.1.

Standard
EN 1996-1-1-2005-a1:2012, clause 6.1.2.1, Eq. (6.2)
Result
NRd\displaystyle N_{\mathrm{Rd}} in kN/m

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
NRd\displaystyle N_{\mathrm{Rd}} = 468 kN/m= 0.65 · (240 mm) · (3 N/mm²)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Masonry.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.