Design · Masonry
Capacity reduction factor at mid-height of wall (slenderness and eccentricity)
Capacity reduction factor at mid-height of a masonry wall according to Annex G: Φm = A1 · exp(-u² / 2).
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Design mid-height eccentricity | mm | ≥ 0 | |
| Thickness of wall | mm | > 0 | |
| Effective height of wall | mm | > 0 | |
| Effective thickness of wall | mm | > 0 | |
| Characteristic compressive strength of masonry | N/mm² | > 0 | |
| Short-term modulus of elasticity | N/mm² | > 0 | |
| Mid-height reduction factor | – | Result |
Valid if
Worked example
= 24 mm · = 240 mm · = 2,880 mm · = 240 mm · = 5 N/mm² · = 5,000 N/mm²
= 0.700185 · Source: hand calculation
Scope and standard
EN 1996-1-1, clause 6.1.2.2 and Annex G (for e_mk < t / 2).
- Standard
- EN 1996-1-1-2005-a1:2012, clause Annex G, Eq. (G.1)
- Result
- (dimensionless)
Reference to clause and equation, no standard text. The description is written in our own words.