Design · Masonry
Design eccentricity at top or bottom of masonry wall
Design eccentricity at the top or bottom of a wall combining load moment, horizontal actions and initial eccentricity, with minimum 0.05 · t.
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Design bending moment at top or bottom of wall | N | ||
| Design vertical load at top or bottom of wall | kN/m | > 0 | |
| Eccentricity resulting from horizontal loads | mm | ≥ 0 | |
| Initial accidental eccentricity | mm | ≥ 0 | |
| Thickness of wall | mm | > 0 | |
| Design end eccentricity | mm | Result |
Worked example
= 4,000 N · = 200 kN/m · = 0 mm · = 6 mm · = 240 mm
= 26 mm · Source: hand calculation
Scope and standard
EN 1996-1-1, clause 6.1.2.2.
- Standard
- EN 1996-1-1-2005-a1:2012, clause 6.1.2.2, Eq. (6.5)
- Result
- in mm
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
- Explain the formulastep by step
- Calculate for my dimensionsenter values, check the result
- Compare with a catalog sectionformula value and table value
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
The search starts in Design › Masonry.
Miaknows the formula catalog and asks for what is missing.