Design preloading force for high-strength bolts according to EN 1993-1-8 eq. 3.7: Fp,C = 0.7 · fub · As.

Fp,C=0.7⋅fub⋅As\displaystyle F_{p,\mathrm{C}} = 0.7 \cdot f_{ub} \cdot A_{s}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

FpCAsfub

Formula and quantities

SymbolNameUnitNote
fub\displaystyle f_{ub}Bolt ultimate tensile strengthN/m²
As\displaystyle A_{s}Tensile stress area of boltmm²
Fp,C\displaystyle F_{p,\mathrm{C}}Design preloading forcekNResult

Worked example

fub\displaystyle f_{ub} = 800,000,000 N/m² · As\displaystyle A_{s} = 245 mm²

Fp,C\displaystyle F_{p,\mathrm{C}} = 137.2 kN

Standard and source

Result
Fp,C\displaystyle F_{p,\mathrm{C}} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Fp,C\displaystyle F_{p,\mathrm{C}} = 137.2 kN= 0.7 · (800,000,000 N/m²) · (245 mm²)