Design · Steel
Column web panel design shear resistance Vwp,Rd
Plastic design shear resistance of an unstiffened column web panel according to EN 1993-1-8 6.2.6.1 eq. 6.1: Vwp,Rd = 0.9 · fy,wc · Avc / (√(3) · γM0).
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Column web yield strength | N/m² | ||
| Column shear area | mm² | ||
| Partial factor gamma_M0 | 1 | ||
| Column web panel shear resistance | kN | Result |
Worked example
= 355,000,000 N/m² · = 2,500 mm² · = 1
= 461.16 kN
Standard and source
- Standard
- EN 1993-1-8:2005
- Result
- in kN
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
- Explain the formulastep by step
- Calculate for my memberwith Mia in CALC
- Compare with RFEM/RSTAB resultshand calculation versus model
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
The search starts in Design › Steel.
Miaknows the formula catalog and asks for what is missing.