Design · Steel
Bolt tensile design strength (LRFD, AISC)
Design tensile strength of a single bolt according to ANSI/AISC 360-22 Section J3.6 Eq. J3-1: Rd = φ · Fnt · Ab.
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Resistance factor (0.75) | 1 | ||
| Nominal tensile stress of bolt | N/m² | ||
| Nominal unthreaded body area of bolt | mm² | ||
| Design bolt tensile strength | kN | Result |
Worked example
= 0.75 1 · = 620,000,000 N/m² · = 314.16 mm²
= 146.08 kN
Standard and source
- Standard
- AISC 360-22
- Result
- in kN
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
- Explain the formulastep by step
- Calculate for my memberwith Mia in CALC
- Compare with RFEM/RSTAB resultshand calculation versus model
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
The search starts in Design › Steel.
Miaknows the formula catalog and asks for what is missing.