Design · Steel
Bolt combined shear and tension interaction check
Combined shear and tension interaction check per bolt according to EN 1993-1-8 Table 3.4: η = Fv,Ed / Fv,Rd + Ft,Ed / (1.4 · Ft,Rd) <= 1.0.
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Design shear force per bolt | kN | ||
| Design shear resistance per bolt | kN | ||
| Design tension force per bolt | kN | ||
| Design tension resistance per bolt | kN | ||
| Interaction utilization ratio | 1 | Result |
Worked example
= 30 kN · = 60 kN · = 42 kN · = 100 kN
= 0.8
Standard and source
- Standard
- EN 1993-1-8:2005
- Result
- in 1
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
- Explain the formulastep by step
- Calculate for my memberwith Mia in CALC
- Compare with RFEM/RSTAB resultshand calculation versus model
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
The search starts in Design › Steel.
Miaknows the formula catalog and asks for what is missing.