Structural analysis · Columns and stability

Buckling reduction factor χ

  • Type: Property
  • Version 1

Buckling reduction factor χ = 1 / (Φ + √(Φ² - λ̄²)) according to EN 1993-1-1 eq. (6.49).

χ=1Φ+Φ2−λˉ2\displaystyle \chi = \frac{1}{\Phi + \sqrt{\Phi^2 - \bar{\lambda}^2}}
  • General formula, independent of standards
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

λ

Formula and quantities

SymbolNameUnitNote
Φ\displaystyle \PhiAuxiliary buckling factor–
λˉ\displaystyle \bar{\lambda}Relative slenderness–
χ\displaystyle \chiBuckling reduction factor–Result

Worked example

Φ\displaystyle \Phi = 0.883 · λˉ\displaystyle \bar{\lambda} = 0.8

χ\displaystyle \chi = 0.7957 · Source: 1 / (0.883 + sqrt(0.883² - 0.64)) = 0.7957

Scope and standard

Flexural buckling of steel members, EN 1993-1-1.

Result
χ\displaystyle \chi (dimensionless)

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

χ\displaystyle \chi = 0.795703= 1 / (0.883 + sqrt(0.883² - 0.8²))