構造解析 · 柱と安定性

座屈低減係数χ

  • タイプ:特性値
  • バージョン1

座屈削減係数 χ = 1 / (Φ + √(Φ² - λ̄²))(EN 1993-1-1 式(6.49)による)。

χ=1Φ+Φ2−λˉ2\displaystyle \chi = \frac{1}{\Phi + \sqrt{\Phi^2 - \bar{\lambda}^2}}
  • General formula, independent of standards
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

λ

Formula and quantities

SymbolNameUnitNote
Φ\displaystyle \Phi補助座屈係数–
λˉ\displaystyle \bar{\lambda}相対細長比–
χ\displaystyle \chi座屈低減係数–Result

例題

Φ\displaystyle \Phi = 0.883 · λˉ\displaystyle \bar{\lambda} = 0.8

χ\displaystyle \chi = 0.7957 · Source: 1 / (0.883 + sqrt(0.883² - 0.64)) = 0.7957

Scope and standard

鋼部材の曲げ座屈、EN 1993-1-1。

Result
χ\displaystyle \chi (dimensionless)

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

χ\displaystyle \chi = 0.795703= 1 / (0.883 + sqrt(0.883² - 0.8²))