Design · Steel
Design plastic tension resistance of cross-section Npl,Rd
Design plastic tension resistance of the gross cross-section: Npl,Rd = A · fy / γM0.
Call in Calculate moden_pl_rd_ec3(A; f_y; gamma_M0)
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Cross-sectional area | m² | ||
| Yield strength | N/mm² | ||
| Partial factor for cross-section resistance | – | ||
| Design plastic tension resistance | kN | Result |
Worked example
= 0.005383 m² · = 235 N/mm² · = 1
= 1,265.01 kN · Source: EN 1993-1-1:2005 Eq. (6.6)
Scope and standard
Tension members without fastener holes or with holes designed for net section check.
- Standard
- EN 1993-1-1:2005, clause 6.2.3 (2), Eq. (6.6)
- Result
- in kN
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
- Explain the formulastep by step
- Calculate for my memberwith Mia in CALC
- Compare with RFEM/RSTAB resultshand calculation versus model
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
The search starts in Design › Steel.
Miaknows the formula catalog and asks for what is missing.