Design · Steel

Design joint bearing strength under base plate fjd

  • Type: Resistance
  • Version 1
  • reviewed on 11/10/2026

Design bearing strength of concrete joint under column base plate according to EN 1993-1-8 6.2.5 eq. 6.6: fjd = (2 / 3) · kj · fck / γc.

fjd=(2/3)⋅kj⋅fck/γc\displaystyle f_{jd} = (2 / 3) \cdot k_{j} \cdot f_{ck} / \gamma _{\mathrm{c}}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

fjdfckkj

Formula and quantities

SymbolNameUnitNote
kj\displaystyle k_{j}Joint concentration factor1
fck\displaystyle f_{ck}Characteristic compressive cylinder strengthN/m²
γc\displaystyle \gamma_{\mathrm{c}}Partial safety factor for concrete1
fjd\displaystyle f_{jd}Design bearing strength of jointN/m²Result

Worked example

kj\displaystyle k_{j} = 1.5 · fck\displaystyle f_{ck} = 30,000,000 N/m² · γc\displaystyle \gamma_{\mathrm{c}} = 1.5

fjd\displaystyle f_{jd} = 20,000,000 N/m²

Standard and source

Result
fjd\displaystyle f_{jd} in MPa

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
fjd\displaystyle f_{jd} = 20,000,000 N/m²= (2 / 3) · (1.5 1) · (30,000,000 N/m²) / (1.5 1)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Steel.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.