Design · Steel
Euler critical buckling force Ncr
Elastic critical buckling force of a pin-ended column: Ncr = π² · E · I / Lcr².
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Modulus of elasticity | N/mm² | ||
| Second moment of area | m⁴ | ||
| Buckling length | m | ||
| Euler critical buckling force | kN | Result |
Worked example
= 210,000 N/mm² · = 8.356e-5 m⁴ · = 5 m
= 6,927.81 kN · Source: hand calculation
Scope and standard
Elastic buckling analysis of uniform compression members (EN 1993-1-1, clause 6.3.1.2).
- Standard
- EN 1993-1-1:2005, clause 6.3.1.2
- Result
- in kN
Reference to clause and equation, no standard text. The description is written in our own words.