Elastic critical buckling force of a pin-ended column: Ncr = π² · E · I / Lcr².

Ncr=π2⋅E⋅ILcr2\displaystyle N_{\mathrm{cr}} = \frac{\pi^2 \cdot E \cdot I}{L_{\mathrm{cr}}^2}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

NcrLcr

Formula and quantities

SymbolNameUnitNote
E\displaystyle EModulus of elasticityN/mm²
I\displaystyle ISecond moment of aream⁴
Lcr\displaystyle L_{\mathrm{cr}}Buckling lengthm
Ncr\displaystyle N_{\mathrm{cr}}Euler critical buckling forcekNResult

Worked example

E\displaystyle E = 210,000 N/mm² · I\displaystyle I = 8.356e-5 m⁴ · Lcr\displaystyle L_{\mathrm{cr}} = 5 m

Ncr\displaystyle N_{\mathrm{cr}} = 6,927.81 kN · Source: hand calculation

Scope and standard

Elastic buckling analysis of uniform compression members (EN 1993-1-1, clause 6.3.1.2).

Standard
EN 1993-1-1:2005, clause 6.3.1.2
Result
Ncr\displaystyle N_{\mathrm{cr}} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Ncr\displaystyle N_{\mathrm{cr}} = 6,927.51 kN= pi² · (210,000 N/mm²) · (8.356e-5 m⁴) / (5 m)²

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Steel.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.