Design · Steel

Elastic-region flexural buckling stress Fcr (AISC)

  • Type: Property
  • Version 1
  • reviewed on 11/15/2026

Critical flexural buckling stress Fcr for slender columns with Lc / r > 4.71 · √(E / Fy) according to ANSI/AISC 360-22 Section E3 Eq. E3-3: Fcr = 0.877 · Fe.

Fcr=0.877⋅Fe\displaystyle F_{\mathrm{cr}} = 0.877 \cdot F_{e}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

Fcr

Formula and quantities

SymbolNameUnitNote
Fe\displaystyle F_{e}Elastic buckling stressN/m²
Fcr\displaystyle F_{\mathrm{cr}}Critical buckling stressN/m²Result

Worked example

Fe\displaystyle F_{e} = 150,000,000 N/m²

Fcr\displaystyle F_{\mathrm{cr}} = 131,550,000 N/m²

Standard and source

Standard
AISC 360-22
Result
Fcr\displaystyle F_{\mathrm{cr}} in MPa

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Fcr\displaystyle F_{\mathrm{cr}} = 131,550,000 N/m²= 0.877 · (150,000,000 N/m²)