Design · Steel
Shear fatigue cut-off limit Δτ,L (EN 1993-1-9)
Cut-off limit for shear stress ranges at 100 million cycles according to EN 1993-1-9 Clause 7.1(1): ΔτL = 0.457 · ΔτC.
- EN 1993-1-9:2005
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Shear detail category reference strength at 2 million cycles | N/m² | ||
| Shear fatigue cut-off limit | N/m² | Result |
Worked example
= 80,000,000 N/m²
= 36,560,000 N/m²
Standard and source
- Standard
- EN 1993-1-9:2005
- Result
- in MPa
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
- Explain the formulastep by step
- Calculate for my dimensionsenter values, check the result
- Compare with a catalog sectionformula value and table value
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
The search starts in Design › Steel.
Miaknows the formula catalog and asks for what is missing.