Design · Connections

Joint bending moment utilization ratio ηj,M

  • Type: Verification
  • Version 1
  • reviewed on 11/13/2026

Verification of a moment-resisting steel joint under design bending moment: ηj,M = Mj,Ed / Mj,Rd.

ηj,M=Mj,Ed/Mj,Rd\displaystyle \eta _{j,M} = M_{j,\mathrm{Ed}} / M_{j,\mathrm{Rd}}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

MjEd

Formula and quantities

SymbolNameUnitNote
Mj,Ed\displaystyle M_{j,\mathrm{Ed}}Design bending moment applied to jointNm
Mj,Rd\displaystyle M_{j,\mathrm{Rd}}Design moment resistance of jointNm
ηj,M\displaystyle \eta_{j,M}Joint moment utilization ratio1Result

Worked example

Mj,Ed\displaystyle M_{j,\mathrm{Ed}} = 145,000 Nm · Mj,Rd\displaystyle M_{j,\mathrm{Rd}} = 185,000 Nm

ηj,M\displaystyle \eta_{j,M} = 0.784 1

Standard and source

Result
ηj,M\displaystyle \eta_{j,M} in 1

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
ηj,M\displaystyle \eta_{j,M} = 0.783784 1= (145,000 Nm) / (185,000 Nm)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Connections.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.