Design · Connections

Long bolted joint reduction factor βLf

  • Type: Coefficient
  • Version 1
  • reviewed on 11/13/2026

Reduction factor for the design shear resistance of bolts in long joints (Lj > 15 · d): βLf = 1 - (Lj - 15 · d) / (200 · d).

βLf=1−(Lj−15⋅d)/(200⋅d)\displaystyle \beta _{Lf} = 1 - (L_{j} - 15 \cdot d) / (200 \cdot d)
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

Lj

Formula and quantities

SymbolNameUnitNote
Lj\displaystyle L_{j}Joint length between centres of end fastenersmm
d\displaystyle dNominal bolt diametermm
βLf\displaystyle \beta_{Lf}Long joint reduction factor1Result

Worked example

Lj\displaystyle L_{j} = 600 mm · d\displaystyle d = 20 mm

βLf\displaystyle \beta_{Lf} = 0.925 1

Standard and source

Result
βLf\displaystyle \beta_{Lf} in 1

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
βLf\displaystyle \beta_{Lf} = 0.925 1= 1 - ((600 mm) - 15 · (20 mm)) / (200 · (20 mm))

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Connections.

Miaknows the formula catalog and asks for what is missing.