Design · Steel

Web resistance to transverse patch loading FRd (EN 1993-1-5)

  • Type: Property
  • Version 1
  • reviewed on 11/24/2026

Design resistance of a web to local transverse forces (patch loading) according to EN 1993-1-5 Clause 6.2(1): FRd = fyw · χF · ly · tw / γM1.

FRd=fyw⋅χF⋅ly⋅tw/γM1\displaystyle F_{\mathrm{Rd}} = f_{yw} \cdot \chi _{F} \cdot l_{y} \cdot t_{w} / \gamma _{\mathrm{M1}}
  • EN 1993-1-5:2006
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

Formula and quantities

SymbolNameUnitNote
fyw\displaystyle f_{yw}Web steel yield strengthN/m²
χF\displaystyle \chi_{F}Patch loading reduction factor1
ly\displaystyle l_{y}Effective loaded lengthmm
tw\displaystyle t_{w}Web thicknessmm
γM1\displaystyle \gamma_{\mathrm{M1}}Partial factor gamma_M11
FRd\displaystyle F_{\mathrm{Rd}}Design patch loading resistancekNResult

Worked example

fyw\displaystyle f_{yw} = 355,000,000 N/m² · χF\displaystyle \chi_{F} = 0.65 · ly\displaystyle l_{y} = 340 mm · tw\displaystyle t_{w} = 10 mm · γM1\displaystyle \gamma_{\mathrm{M1}} = 1.1

FRd\displaystyle F_{\mathrm{Rd}} = 713.227 kN

Standard and source

Standard
EN 1993-1-5:2006
Result
FRd\displaystyle F_{\mathrm{Rd}} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
FRd\displaystyle F_{\mathrm{Rd}} = 713.227 kN= (355,000,000 N/m²) · (0.65 1) · (340 mm) · (10 mm) / (1.1 1)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Steel.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.