Reduction factor kc for flexural column buckling: kc = min(1.0 / (k + √(k² - λrel,c²)); 1.0).

kc=min⁡(1k+k2−λrel,c2;  1,0)\displaystyle k_{\mathrm{c}} = \min\left(\frac{1}{k + \sqrt{k^2 - \lambda_{\text{rel},\mathrm{c}}^2}};\; 1{,}0\right)
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

λrel,c

Formula and quantities

SymbolNameUnitNote
k\displaystyle kAuxiliary buckling parameter–
λrel,c\displaystyle \lambda_{\text{rel},\mathrm{c}}Relative slenderness ratio–
kc\displaystyle k_{\mathrm{c}}Buckling reduction factor–Result

Worked example

k\displaystyle k = 1.69593 · λrel,c\displaystyle \lambda_{\text{rel},\mathrm{c}} = 1.46903

kc\displaystyle k_{\mathrm{c}} = 0.39318 · Source: EN 1995-1-1:2004 Eq. (6.25)

Scope and standard

Timber compression members according to EN 1995-1-1, clause 6.3.2.

Standard
EN 1995-1-1:2004, clause 6.3.2 (3), Eq. (6.25)
Result
kc\displaystyle k_{\mathrm{c}} (dimensionless)

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

kc\displaystyle k_{\mathrm{c}} = 0.393181= min(1.0 / (1.69593 + sqrt(1.69593² - 1.46903²)); 1.0)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Timber.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.