Depth factor kh for solid timber in bending and tension
Size-effect factor kh for rectangular solid timber with depth h < 150 mm: kh = min((150 mm / h)⁰.2; 1.3).
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Depth of cross-section | mm | ||
| Depth factor k_h | – | Result |
Worked example
= 100 mm
= 1.08447 · Source: EN 1995-1-1:2004 Eq. (3.1)
Scope and standard
Solid timber under bending or tension with depth h < 150 mm according to EN 1995-1-1, clause 3.2.
- Standard
- EN 1995-1-1:2004, clause 3.2 (3), Eq. (3.1)
- Result
- (dimensionless)
Reference to clause and equation, no standard text. The description is written in our own words.