Design · Timber
Effective contact length for compression perpendicular to grain lef
Effective bearing length taking into account load distribution: lef = l + min(a; 30 mm) + min(l1; 30 mm).
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Actual contact length | mm | ||
| Distance from end of member | mm | ||
| Adjacent bearing distance or overhang | mm | ||
| Effective contact length | mm | Result |
Worked example
= 100 mm · = 40 mm · = 50 mm
= 160 mm · Source: EN 1995-1-1:2004 Eq. (6.4)
Scope and standard
Timber contact areas according to EN 1995-1-1, clause 6.1.5.
- Standard
- EN 1995-1-1:2004, clause 6.1.5 (1), Eq. (6.4)
- Result
- in mm
Reference to clause and equation, no standard text. The description is written in our own words.