Design · Timber

Design value of timber strength property fd

  • Type: Property
  • Version 1
  • reviewed on 11/9/2026

Design value of a timber material strength property: fd = kmod · fk / γM.

fd=kmod⋅fkγM\displaystyle f_{\mathrm{d}} = k_{\text{mod}} \cdot \frac{f_{k}}{\gamma_{M}}

Call in Calculate modef_d_ec5(k_mod; f_k; gamma_M)

Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

Formula and quantities

SymbolNameUnitNote
kmod\displaystyle k_{\text{mod}}Modification factor for duration of load and moisture–
fk\displaystyle f_{k}Characteristic strength propertyN/mm²
γM\displaystyle \gamma_{M}Partial factor for material property–
fd\displaystyle f_{\mathrm{d}}Design strength propertyN/mm²Result

Worked example

kmod\displaystyle k_{\text{mod}} = 0.8 · fk\displaystyle f_{k} = 24 N/mm² · γM\displaystyle \gamma_{M} = 1.3

fd\displaystyle f_{\mathrm{d}} = 14.7692 N/mm² · Source: EN 1995-1-1:2004 Eq. (2.14)

Scope and standard

Timber and wood-based materials according to EN 1995-1-1, clause 2.4.1.

Standard
EN 1995-1-1:2004, clause 2.4.1 (1), Eq. (2.14)
Result
fd\displaystyle f_{\mathrm{d}} in N/mm²

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
fd\displaystyle f_{\mathrm{d}} = 14.7692 N/mm²= 0.8 · (24 N/mm²) / 1.3

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Timber.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.