Design load-carrying capacity per shear plane according to EN 1995-1-1 2.4.3: Fv,Rd = kmod · Fv,Rk / γM.

Fv,Rd=kmod⋅Fv,Rk/γM\displaystyle F_{v,\mathrm{Rd}} = k_{mod} \cdot F_{v,Rk} / \gamma _{M}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

FvRd

Formula and quantities

SymbolNameUnitNote
kmod\displaystyle k_{mod}Modification factor for duration and moisture1
Fv,Rk\displaystyle F_{v,Rk}Characteristic load-carrying capacitykN
γM\displaystyle \gamma_{M}Partial factor for connection1
Fv,Rd\displaystyle F_{v,\mathrm{Rd}}Design load-carrying capacitykNResult

Worked example

kmod\displaystyle k_{mod} = 0.8 · Fv,Rk\displaystyle F_{v,Rk} = 15 kN · γM\displaystyle \gamma_{M} = 1.3

Fv,Rd\displaystyle F_{v,\mathrm{Rd}} = 9.231 kN

Standard and source

Result
Fv,Rd\displaystyle F_{v,\mathrm{Rd}} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Fv,Rd\displaystyle F_{v,\mathrm{Rd}} = 9.23077 kN= (0.8 1) · (15 kN) / (1.3 1)