Design · Timber

Effective residual timber width for 3-sided fire (EN 1995-1-2)

  • Type: Property
  • Version 1
  • reviewed on 11/21/2026

Effective residual cross-section width of a rectangular timber beam exposed to fire on three sides according to EN 1995-1-2 Clause 4.2.2: bef = b - 2 · def.

bef=b−2⋅def\displaystyle b_{\mathrm{ef}} = b - 2 \cdot d_{\mathrm{ef}}
  • EN 1995-1-2:2004
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

yzbefdef

Formula and quantities

SymbolNameUnitNote
b\displaystyle bOriginal timber section widthmm
def\displaystyle d_{\mathrm{ef}}Effective charring depthmm
bef\displaystyle b_{\mathrm{ef}}Effective residual widthmmResult

Worked example

b\displaystyle b = 200 mm · def\displaystyle d_{\mathrm{ef}} = 49 mm

bef\displaystyle b_{\mathrm{ef}} = 102 mm

Standard and source

Standard
EN 1995-1-2:2004
Result
bef\displaystyle b_{\mathrm{ef}} in mm

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
bef\displaystyle b_{\mathrm{ef}} = 102 mm= (200 mm) - 2 · (49 mm)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Timber.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.