Effective residual timber area for 4-sided fire (EN 1995-1-2)
Effective residual cross-sectional area of a rectangular timber column exposed to fire on all four sides according to EN 1995-1-2 Clause 4.2.2: Aef = (b - 2 · def) · (h - 2 · def).
- EN 1995-1-2:2004
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Original timber section width | mm | ||
| Original timber section depth | mm | ||
| Effective charring depth | mm | ||
| Effective residual cross-sectional area | mm² | Result |
Worked example
= 240 mm · = 240 mm · = 49 mm
= 20,164 mm²