Design · Timber

Effective residual timber area for 4-sided fire (EN 1995-1-2)

  • Type: Property
  • Version 1
  • reviewed on 11/21/2026

Effective residual cross-sectional area of a rectangular timber column exposed to fire on all four sides according to EN 1995-1-2 Clause 4.2.2: Aef = (b - 2 · def) · (h - 2 · def).

Aef=(b−2def)⋅(h−2def)\displaystyle A_{\mathrm{ef}} = (b - 2 d_{\mathrm{ef}}) \cdot (h - 2 d_{\mathrm{ef}})
  • EN 1995-1-2:2004
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

yzbh

Formula and quantities

SymbolNameUnitNote
b\displaystyle bOriginal timber section widthmm
h\displaystyle hOriginal timber section depthmm
def\displaystyle d_{\mathrm{ef}}Effective charring depthmm
Aef\displaystyle A_{\mathrm{ef}}Effective residual cross-sectional areamm²Result

Worked example

b\displaystyle b = 240 mm · h\displaystyle h = 240 mm · def\displaystyle d_{\mathrm{ef}} = 49 mm

Aef\displaystyle A_{\mathrm{ef}} = 20,164 mm²

Standard and source

Standard
EN 1995-1-2:2004
Result
Aef\displaystyle A_{\mathrm{ef}} in mm²

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Aef\displaystyle A_{\mathrm{ef}} = 20,164 mm²= ((240 mm) - 2 · (49 mm)) · ((240 mm) - 2 · (49 mm))

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Timber.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.