Actions and loads · Traffic loads

LM1 equivalent line load per lane pL1

  • Type: Action
  • Version 1
  • reviewed on 11/13/2026

Longitudinal line load obtained by integrating adjusted LM1 UDL over notional lane width wl: pL1 = αq1 · q1k · wl.

pL1=αq1⋅q1k⋅wl\displaystyle p_{L1} = \alpha _{q1} \cdot q_{1k} \cdot w_{l}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

pL1

Formula and quantities

SymbolNameUnitNote
αq1\displaystyle \alpha_{q1}Adjustment factor for UDL on Lane 11
q1k\displaystyle q_{1k}Characteristic UDL on Lane 1N/m²
wl\displaystyle w_{l}Width of notional lanem
pL1\displaystyle p_{L1}Equivalent lane line loadkN/mResult

Worked example

αq1\displaystyle \alpha_{q1} = 1 · q1k\displaystyle q_{1k} = 9,000 N/m² · wl\displaystyle w_{l} = 3 m

pL1\displaystyle p_{L1} = 27 kN/m

Standard and source

Result
pL1\displaystyle p_{L1} in kN/m

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
pL1\displaystyle p_{L1} = 27 kN/m= (1 1) · (9,000 N/m²) · (3 m)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Actions and loads › Traffic loads.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.