Actions and loads · Traffic loads

Adjusted LM1 uniformly distributed load qik,adj

  • Type: Action
  • Version 1
  • reviewed on 11/13/2026

Characteristic uniformly distributed load of Load Model 1 adjusted by National Annex factor αq: qik,adj = αq · qik.

qik,adj=αq⋅qik\displaystyle q_{ik,adj} = \alpha _{q} \cdot q_{ik}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

qikadj

Formula and quantities

SymbolNameUnitNote
αq\displaystyle \alpha_{q}Adjustment factor for UDL traffic load1
qik\displaystyle q_{ik}Characteristic UDL traffic load (9.0 or 2.5 kN/m2)N/m²
qik,adj\displaystyle q_{ik,adj}Adjusted UDL traffic loadN/m²Result

Worked example

αq\displaystyle \alpha_{q} = 1.33 · qik\displaystyle q_{ik} = 9,000 N/m²

qik,adj\displaystyle q_{ik,adj} = 11,970 N/m²

Standard and source

Result
qik,adj\displaystyle q_{ik,adj} in kPa

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
qik,adj\displaystyle q_{ik,adj} = 11,970 N/m²= (1.33 1) · (9,000 N/m²)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Actions and loads › Traffic loads.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.