Actions and loads · Wind actions

External wind force on building zone

  • Type: Action
  • Version 1
  • reviewed on 11/10/2026

External wind force Fwe acting on a loaded reference surface area of an individual wall or roof zone according to EN 1991-1-4 Clause 5.2.

Fwe=cpe⋅qp⋅Aref\displaystyle F_{we} = c_{pe} \cdot q_{p} \cdot A_{ref}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

ArefFweqp

Formula and quantities

SymbolNameUnitNote
cpe\displaystyle c_{pe}External pressure coefficient–
qp\displaystyle q_{p}Peak velocity pressurekN/m²
Aref\displaystyle A_{ref}Reference surface aream²
Fwe\displaystyle F_{we}External wind forcekNResult

Worked example

cpe\displaystyle c_{pe} = 0.8 · qp\displaystyle q_{p} = 0.75 kN/m² · Aref\displaystyle A_{ref} = 50 m²

Fwe\displaystyle F_{we} = 30 kN

Standard and source

Standard
EN 1991-1-4:2005, clause 5.2
Result
Fwe\displaystyle F_{we} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Fwe\displaystyle F_{we} = 30 kN= 0.8 · (0.75 kN/m²) · (50 m²)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Actions and loads › Wind actions.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.