we=qp(ze)⋅cpe\displaystyle w_{e} = q_{p}(z_{e})·c_{pe}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

qp(ze)wecpe

Formula and quantities

SymbolNameUnitNote
qp(ze)\displaystyle q_{p}(z_{e})Peak velocity pressure at the reference heightkN/m²
cpe\displaystyle c_{pe}External pressure coefficient–
we\displaystyle w_{e}External wind pressurekN/m²Result

Worked examples

Windward wall, zone D

qp(ze)\displaystyle q_{p}(z_{e}) = 0.9 kN/m² · cpe\displaystyle c_{pe} = 0.8

we\displaystyle w_{e} = 0.72 kN/m² · Source: hand calculation

Roof suction

qp(ze)\displaystyle q_{p}(z_{e}) = 0.9 kN/m² · cpe\displaystyle c_{pe} = -1.2

we\displaystyle w_{e} = -1.08 kN/m² · Source: hand calculation

Standard and source

Standard
EN 1991-1-4:2005, clause 5.2(1), Eq. (5.1)
Result
we\displaystyle w_{e} in kN/m²

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
we\displaystyle w_{e} = 0.72 kN/m²= (0.9 kN/m²) · 0.8

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Actions and loads › Wind actions.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.